Switches, including dimmer switches, shall be grounded and shall provide a means to ground metal plates. NEC 250-134 and 370-4 Box Covers and Plates Metal boxes, cover plates, and plaster rings shall be grounded. Visible and accessible, the conductor with white colored insulation in type NM cable may be used as an ungrounded conductor. NEC 200.7(C) Wiring Methods wiring Where permanently re-identified at each location where it is NEC 110-14 and 300-15 Wire Splices All splices, including ground wires, shall be made with an approved splice cap or wire nut and shall be made in approved electrical boxes or enclosures. In boxes with more than one ground wire, the ground wires shall be spliced with a wire tail, or pig tail attached to the grounding terminal screw. NEC 110-14 Only one conductor shall be installed under a terminal screw. NEC 110.14 Underground Wiring Underground wiring splicing Wire splicing means for direct burial conductors shall be listed for such use. NEC 110.14 Electrical Services wire conductorsListed anti-oxidant compound shall be used on all aluminum conductor terminations, unless product information specifically states that it is not required. NEC 110.14 Underground WiringWire splicing means for direct burial conductors shall be listed for such use. Contact your local building authority for complete information. The codes shown are examples only and may not be current or accurate for your application or jurisdiction.
Why do i have colonial flex type nm 600 volts 14/2 ground wire in hot water baseboard heater code#
In boxes with more than one ground wire, the ground wires shall be spliced with a wire tail or pig tail attached to the grounding terminal screw of the device.Įxamples of Electrical Codes for Home Wiring Code Adoption Information: NEC 110.14 Wiring Methods for Conductors and Screw Terminal Only one conductor shall be installed under a terminal screw. If openings in non-metallic boxes are broken out and not used, the entire box shall be replaced. NEC 110-12 and 370-18 Unused openings in boxes shall be effectively closed. When openings in non-metallic boxes are broken out and not used, the entire box must be replaced. Unused openings in boxes shall be effectively closed. Understanding the importance of Proper Wiring Methods, and wiring according to Electrical Codes.